bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

61 Oil Pressure-oil Temperature-oil Gauge > < 4 RA Replacing Wiring Harness Section For Ignition Coil (N52K, N51)|Page 442
Page 3
background image

Press locking tab (1) in direction of arrow and pull contact
carrier (2) out of housing.

Work step

Note:

Disconnect positive lead at jump-start connection point

Disconnect ground cables

Unlock plug connections on ignition coils and disconnect

Unlock cable duct on cylinder head cover and detach

Unlock plug on eccentric shaft sensor and disconnect

Unlock plug on positioning motor for eccentric shaft and disconnect

Unlock plug on both solenoid valves and disconnect

Unlock plug on inlet and exhaust camshaft sensors and disconnect

Unlock plug on A/C compressor and disconnect

Unlock plug on oil pressure switch and disconnect

Unlock plug on coolant temperature sensor and disconnect

Disconnect connector strip from fuel rail

Remove front underbody protection

Unlock plug on electric coolant pump and disconnect

Unlock plug on coolant thermostat and disconnect

Disconnect engine ground connection

Tightening torque 12 52 3AZ

.

Replace screw.

Note:

Check stored fault messages.

Now clear the fault memory.

RA  Replacing wiring harness section for ignition coil (N52K, N51)

BMW AG - TIS

22.01.2013  03:46

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 3 -

61 Oil Pressure-oil Temperature-oil Gauge > < 4 RA Replacing Wiring Harness Section For Ignition Coil (N52K, N51)|Page 442