bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Fuel Supply System (petrol_gasoline)|Page 489 > < 2 RA Fuel Supply System (petrol_gasoline)|Page 487
Page 3
background image

The fuel is routed from the electric fuel pump via the fuel feed line and the fuel filter/pressure regulator unit to the fuel
rail.

Pressure regulator and fuel filter are incorporated in a single unit in the tank. There is thus no need for a fuel return line.

The fuel passes through the pressure regulator into the left side of the fuel tank and thereby drives a suction jet pump.
This pump repumps the fuel from the left side of the tank to the right side.

The fuel rail is return-free.

Tank venting system (US version):

The fuel tank is vented during refuelling via the refuelling vent line.

Because of its large cross-section, the refuelling vent line directs the displaced volume (fuel vapours) at high speed

through the expansion volume to the carbon canister.

The activated carbon retains the fuel contained in the fuel vapours. The cleaned air is discharged to atmosphere via

the evaporation line, the tank leak diagnosis module and the dust filter.

During driving, the system tank is vented in the same way via the vent line.

The condensed constituents of the fuel vapours remain in the tank because the tank has an integrated compensating
volume.

The refuelling shutoff valve in the fuel tank is closed by the rising fuel if the fuel tank is overfilled. The ventilation
function is maintained by a second float valve. 

Al three valves are designed as rollover valves. This prevents fuel from escaping from the fuel tank in extreme vehicle
positions (overturning, inclined position).

The carbon canister is regenerated by purging with fresh air.

The DME control unit opens the tank vent valve. Thus the vacuum pressure of the engine intake manifold is applied at

the purge air line. The carbon canister is purged in this way. The fresh air needed for this purpose is supplied via the
tank leak diagnosis module and the dust filter. The fuel constituents bound by the activated carbon are flushed out by
the supplied air and directed via the purge line to the engine for combustion.

This operation is only possible while the engine is running.

Tank venting system (worldwide):

Refer to Tank venting system (US version) with following differences:

1. 

Carbon canister has a smaller capacity.

2. 

No tank leak diagnosis module or dust filter.

Leak diagnosis for tank venting system (US version):

The tank leak diagnosis module (see drawing 5.2) serves to diagnose leakages for the tank venting system within the
on-board diagnosis laid down by legislation.

The tank venting system is pressurised and the pressure loss is detected in the event of a leak.

The tank leak diagnosis module is activated by the DME control unit and detects the pressure loss by way of the power

consumption of the integrated pump. The air required for this purpose is supplied via the dust filter.

The pressure test line establishes the connection between fuel tank and fuel filler neck. This enables a leak to be

detected in the fuel filler pipe - fuel tank cap area.

Determining fill level in fuel tank:

The fuel level is measured by means of lever-type sensors on both sides of the fuel tank. The combination of the
determined ohm values from the right and left lever-type sensors produces the actual level in the fuel tank.

RA  Fuel supply system (petrol/gasoline)

BMW AG - TIS

22.01.2013  03:54

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 3 -

2 RA Fuel Supply System (petrol_gasoline)|Page 489 > < 2 RA Fuel Supply System (petrol_gasoline)|Page 487