When using special tool  11 9 150  in conjunction with

special tool  11 7 030 , 47 Nm on torque wrench scale
corresponds to an actual tightening torque of 50 Nm.

The threads of new oxygen monitor sensors are already

coated with Never Seez Compound.

If an oxygen monitor sensor is reused, only apply a thin and

uniform coat of Never Seez Compound (refer
to BMW Parts Service) to thread.

Oxygen monitor sensor section projecting into exhaust

system branch must not be cleaned or come into contact with
lubricant.

Cover oxygen monitor sensor when applying underseal. 

Check function of DME.