3 Series E36 316i (M43) SAL
64 50 ...
Safety instructions for handling refrigerant
oil
Warning!
Risk of injury!
Refrigerant circuit is under high pressure! Work on the
refrigerant circuit may only be carried out by experts!
Draw off refrigerant without fail BEFORE all repair work on the
refrigerant circuit.
The refrigerant circuit is depressurized AFTER drawing off!
It is absolutely essential to read and observe the relevant
operating instructions for the A/C service unit used!
Protective measures/rules of conduct:
•
Wear protective goggles
•
Wear oil-resistant protective gloves
•
Do not smoke!
•
Observe country-specific safety regulations.
First aid measures:
•
If swallowed: Do NOT induce vomiting, unless expressly
instructed to do so by medical personnel. Do not administer
anything to an unconscious person through their mouth.
Consult a doctor immediately if larger quantities of this
substance are swallowed. Loosen tight-fitting items of
clothing (e.g. collar, tie, belt or similar).
•
Eye contact:Remove contact lenses if worn. In the event of
eye contact, rinse eyes for at least 15 minutes with plenty of
water. It is essential to use WARM WATER. Consult a
doctor.
•
Skin contact: In the event of skin contact, rinse immediately
with plenty of water. Remove contaminated clothes and
shoes. Wash affected clothes before wearing again. Clean
shoes thoroughly before reusing. Call for a doctor.
•
After inhalation: If inhaled, take the person affected outside
into fresh air immediately and keep them under supervision.
Call for a doctor. If breathing difficulties are experienced,
administer additional oxygen. If the person affected stops
breathing, administer the kiss of life.
RA Safety instructions for handling refrigerant oil
BMW AG - TIS
20.01.2013 09:25
Issue status (12/2007) Valid only until next DVD is issued
Copyright