3 Series E36 320i (M52) CONVER
S5 (S213*): Microswitch on trunk lid lock
S6 (S214*): Microswitch on convertible top lid lock, right
* Designation in circuit diagram
Note:
Function of indicator lamp on convertible top operating switch.
Continuous light:
During opening and closing operation.
Intermittent light:
a) Convertible top operating switch is released during opening or closing operation.
b) Convertible top is closed but microswitch (S7) on convertible top cover lock, left (locked), is faulty.
c) Convertible top is open but Hall sensor (HS) on convertible top lid motor is faulty.
S7 (S231*): Microswitch on convertible top lock (locked down)
HS (M100*): Hall sensor on convertible top lid motor
* Designation in circuit diagram
RA Troubleshooting convertible (trunk lid/convertible top, electric motor/fully aut
BMW AG - TIS
07.02.2013 06:57
Issue status (12/2007) Valid only until next DVD is issued
Copyright