Unfasten screws with special tool 54 3 160.
Disconnect connector.
Installation:
After assembly, the fault memory in the cabriolet soft-top
module (CVM) must be cleared and the soft-top module re-
initialized, refer to 54 34 002
and Vehicle Electric/Electronic Test Plan, 3 Series E36.
Check setting:
Disconnect soft-top drive units.
Close and lock soft top.
Connect MoDiC.
microswitch for "soft top closed"
Select switch 4.
Set microswitch in such a way that microswitch cuts in.
Microswitch: tighten adjusting screws.
RA Removing and installing or replacing microswitch - soft top fully raised