54 90 ...

Troubleshooting convertible (rollover protection system)

Note:

CVM = Convertible top module

Fault

Cause

Remedy

Rollover protection bar not ready to
trigger (yellow telltale lights up)

a)

Battery voltage < 10.5 V

b)

Terminal "R" not switched on

c)

Fuses defective

d)

Plug connections interrupted

e)

Rollover sensor defective

f)

Actuator defective

g)

Breaks in wiring

a)

Charge battery, let engine run

b)

Switch on term. "R", check

terminal "R"

c)

Refer to fuse allocation diagram

d)

Repair plug connection

e)

Refer to Workshop Manual

61 35 160

f)

Triggering mechanically and

replacing,

refer to 54 62 001

g)

Refer to Electrical

Troubleshooting Manual E36

Schematics

Yellow telltale lights up

a)

CVM software status SW02

50 releases stored

b)

CVM defective

a)

Resetting counter, refer to

Diagnosis (from SW03 lamp

only lights up when fault occurs

in RPS). Stick adhesive label to

CVM with counter reading

(max. 249)

b)

Refer to Diagnosis

RA  Troubleshooting convertible (rollover protection system)