3 Series E36 325i (M50) CONVER
Unscrew screw. Remove pulse generator.
Installation:
After assembly, make sure that the lead from the pulse sensor
does not contact the water pump drive gear.
Remove cable channel.
Mark plug-in connection (3) on wiring harness and disconnect it.
1 = Plug connection on oil pressure switch
2 = Sensor for cylinder recognition
3 = Impulse sensor on vibration damper
Installation:
Interrogate fault memory of DME-control unit, check faults in
memory then cancel fault memory.
RA Replacing impulse sensor on vibration damper (M50, M50 VANOS)
BMW AG - TIS
08.02.2013 07:21
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 3 -