3 Series E36 M3 (S52) SAL
Press lock (1) in direction of arrow. Pull contact carrier (2) out of
housing (3).
Note:
When the contact carrier is pulled out, the secondary locks of the
socket contacts are raised.
Hold down retaining hook (1) of socket contact in opening of
contact carrier with a small screwdriver.
Pull wire with socket contact in direction of arrow as far as
secondary lock (2).
Note:
The illustration shows an 8-pin socket housing where removal of
the contacts is identical.
Hold down arrester hook in secondary lock (1) again. Pull wire
with socket contact (2) out of contact carrier (3).
Removing MPQ contacts from contact carrier:
Remove contact carrier (1) with MQS contacts from radio plug.
Raise lock (2) on radio plug.
Pull contact carrier (3) out of radio plug.
RA Socket housing (radio plug), Hybrid System MQS/MPQ
BMW AG - TIS
10.02.2013 14:20
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -