Failure or continuous operation of electric fan

E46

Complaint:

1. 

The electric fan (suction fan or pressure fan) fails.

2. 

The electric fan (suction fan or pressure fan) runs on for longer than the maximum
permissible run-on time of 12 minutes when the engine is switched off.

Cause:

Faulty clock regulator in the electric fan.

Affected
vehicles:

E46 
Manufacturing period: start of series production to April 1999.

Procedure:

In case of customer complaint, perform diagnosis with DIS or MoDiC. When doing this,
work through the individual test modules.

If the electric fan is faulty, replace it.

Parts:

Designation

Part number

Quantity

Shroud with fan (suction fan) See Electronic 

Parts Catalogue (ETK)

1

Pressure fan

See Electronic 
Parts Catalogue (ETK)

1

Reimbursement:

Material and labour costs incurred can be claimed through the usual warranty channels
subject to current warranty terms as follows:

Defect code

64 54 92 12 00
This defect code is not contained in the official
Defect Code Catalogue but has been included in
the system, thus enabling warranty claims to be
processed.

Within the scope of a visit to the workshop: 
Read off and clear DME/DDE fault memory and
replace electric fan:

Job number

00 52 772 Shroud with fan (suction fan)

Labour

4 FRUs - M43 and M52
7 FRUs - M47

Within the scope of a visit to the workshop: 
Read off and clear DME/DDE fault memory and
replace electric fan:

Job number

00 52 773 Pressure fan

Labour

7 FRUs

In case of order without additional repair
operations - Read off and clear DME/DDE fault
memory and replace electric fan:

Job number

00 52 171 Shroud with fan (suction fan)

SI  Failure or continuous operation of electric fan E46

BMW AG - TIS

19.01.2013  09:49

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

8 SI Failure Or Continuous Operation Of Electric Fan E46|Page 261 > < 7 SI No Air Throughput In Air Conditioning Mode E46 With Automatic Air Conditioning S|Page 259