16 12 010

Removing and installing/replacing carbon
canister with LDP (leak diagnosis pump)

Release screws (1), lift out expansion rivet (2) and remove cover
(3).

Lever out expansion rivets (4) and remove cover (5).

Unfasten lines (1) ... (3) and detach.

1)

Line to expansion tank

2)

Scavenging air line

3)

Intake line for dust filter

Unfasten plug connection (1).

Release screws (2) and remove carbon canister (3) with leakage
diagnosis pump towards bottom.

Installation:

Press rubber-encased lugs (1) on carbon canister (2) into
mountings (3).