Valvetronic control unit: output stage fault
E46 / N42
Complaint:
Fault code entry DME-2860 in DME control unit: output stage fault
Type of fault: no signal or value / short circuit in engine wiring
The Valvetronic output stage fault can intermittently cause the "Check Engine" lamp to light
up in conjunction with a loss of power. Restarting the engine will rectify this problem. The
above fault entry remains in the DME control unit without the "Check Engine" lamp lighting
up.
Cause:
Hardware fault in Valvetronic output stage
Affected
vehicles:
E46/N42
Manufacturing period: 1st April 2001 to 1st October 2001
Procedure:
In case of customer complaint, a modified Valvetronic control unit with part number
11 37 7 516 809 should be installed.
Parts:
Description:
Part number:
Exchange Valvetronic
control unit
11 37 7 516 809
Reimbursement:
Material and labour costs incurred can be claimed through the usual warranty channels
subject to current warranty terms.
Defect code
11 37 90 02 00
This defect code is not contained in the official
Defect Code Catalogue but has been included in
the system, thus enabling warranty claims to be
processed.
Job number
00 53 729
Labour
3 FRUs
Warranty type
1
Warranty stage
1 (within vehicle warranty)
Warranty stage:
2 (outside vehicle warranty)
Reimbursement is limited to 36 months/100,000 km and only possible until October 2004
.