Rotate crankshaft in direction of engine rotation until special tool
00 2 510 (dial gauge) indicates value specified on injection
pump exactly.

Release locking screw (1) on injection pump.

Remove spacer plate (2) and tighten down locking screw. The
pump shaft is thus blocked.

Tightening Torque,

refer to Technical Data 13 51 13AZ.

Release central nut on injection pump shaft.

Screw in and secure special tool 13 5 190 without forcing screw.