3 Series E46 320d (M47) TOUR
64 51 522
Removing and installing or replacing
expansion valve
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly
filled.
Follow instructions for opening and replacing parts in
refrigerant circuit!
If A/C system is opened for more than 24 hours:
Replacing drier insert for A/C system
Necessary preliminary tasks:
•
Drawing off, evacuating and filling the A/C system are not
included in the time value given for this work operation
•
Remove heater bulkhead
Unfasten nut.
RA Removing and installing or replacing expansion valve
BMW AG - TIS
13.02.2013 02:21
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -