3 Series E46 320d (M47TU) SAL
Note:
For more information on cleaning agent, refer to Service
Information.
For further information on spray apparatus, refer to Special
Tools/Equipment Service Information.
Note:
Make sure the cleaning agent can escape freely from the drain
openings. If necessary, remove rear underbody protection.
Remove limit switch for heater - A/C fan.
Secure adapter for spray lance 64 1 457 with screws (1) of limit
switch for heater - A/C fan.
Seal opening (B) with plug for adapter 64 1 458 .
Insert spray lance 64 1 451 in direction of arrow and secure with
fixture for spray lance 64 1 456 .
RA Cleaning evaporator
BMW AG - TIS
13.02.2013 02:01
Issue status (12/2007) Valid only until next DVD is issued