Caution!
Set pressure regulator on special tool 16 1 171 fully in "-"
direction.
Connect special tool 16 1 171 using compressed air line (1) to
garage compressed air system (8...10 bar).
Connect pressure sensor (2) of Diagnosis and Information System
with measuring range of 0...3.5 bar.
Caution!
Do not connect fast-release coupling (3) of special tool
16 1 171 yet.
Select "Measurement" function on Diagnosis and Information
System (DIS).
Set measuring range in accordance with pressure sensor to 0-3.5
bar.
Using pressure regulator on special tool 16 1 171 , increase
pressure by 0.050 bar.
Connect special tool 16 1 174 to fast-release coupling of special
tool 16 1 171 .
Using pressure regulator on special tool 16 1 171 , reset gauge
pressure in fuel tank to 0.050 bar.
Caution!
Do not under any circumstances increase pressure by more
than 0.100 bar as this would result in damage to the fuel tank
and venting system.
RA Checking fuel tank and tank ventilation system for leaks
BMW AG - TIS
13.02.2013 21:35
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 3 -