bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 SI Installation Instructions For Adapter Wire Set, E46 M57|Page 59 > < 2 SI Master Document For Emissions Test Nominal Values All Series Up To 2003
Page 1
background image

Installation instructions for adapter wire set, E46 M57

Preparatory work:

1. 

Remove the complete microfilter housing.

2. 

Remove lid of electronics box.

a) 

Adapter wire set

b) 

Cable tie, 2x

c) 

Cleaning connector

d) 

Connecting element for cable holder

e) 

Cable holder

Remove grommets (1) and (2) from adapter wire set with part
number 7 790 285.

Installation location of rail pressure sensor B2261.

Unplug and tie back connector (2) from rail pressure sensor (1).

Clean contacts on rail pressure sensor (1) with cleaning
connector (c) by plugging and unplugging the cleaning connector
3 times.

Plug the connector from the adapter wire set onto rail pressure
sensor (1).

Note: 
The intake system does not have to be removed for this work.

SI  Installation instructions for adapter wire set, E46 M57

BMW AG - TIS

15.02.2013  06:51

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

3 SI Installation Instructions For Adapter Wire Set, E46 M57|Page 59 > < 2 SI Master Document For Emissions Test Nominal Values All Series Up To 2003