background image

Release screw (1).

Tightening torque  23 41 7AZ

.

Installation:

Make sure retainer (2) for heat shield is correctly positioned.

Release stud bolt (1) and screw (2).

Tightening torque  23 41 7AZ

.

Remove expansion tank in direction of arrow.

Installation:

Replace sealing ring.

Moisten sealing ring (1) with Pentosin and push onto tank fitting.

Note:

After completing work:

Check fluid level in hydraulic system by means of DIS Tester

"Service Function"

Perform "Teach in transmission" service function by means

of DIS Tester

RA  Replacing expansion tank GS6S37BZ (SMG)

BMW AG - TIS

16.02.2013  00:50