3 Series E46 330xd (M57) SAL
Fig. 2:
Foam mantle around plug connector
Position the plug connector between the adapter cable and the wiring harness centrally in
the opening in the air duct behind the instrument cluster.
Fig. 3:
Routing the adapter cable
Note:
When installing the instrument cluster, take care to ensure that the plug connector
between the vehicle wiring harness and the adapter cable is positioned in such a way
that it will not cause any rattling noises while the vehicle is being driven.
After installation, there must not be a gap between the instrument panel and the
instrument cluster.
Parts:
Adapter cable: Part no. 12 51 7 786 936
Reimbursement:
Material and labour costs incurred can be claimed through the usual warranty channels
subject to current warranty terms as follows:
Defect code
12 51 92 87 00
Refit adapter cable:
Job number
00 52 263
Labour
5 FRUs
Warranty type
1
Warranty stage
1 (within vehicle warranty)
2 (outside vehicle warranty)
Reimbursement is limited to 36 months/100,000 km and only possible until December 2001.
SI Battery charge warning light flickers E46 M47 M57
BMW AG - TIS
15.02.2013 15:42
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -