bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

1 RA Replacing Crankshaft Pulse Generator (N54)|Page 453 > < 3 RA Replacing Spark Plugs (N54, N53)|Page 450
Page 1
background image

12 14 521

Replacing crankshaft pulse generator (N54)

Important!

Read and comply with notes on protection against
electrostatic damage (ESD protection).

Important!

Aluminium screws/bolts must be replaced each time they are 
released.

The end faces of aluminium screws/bolts are painted blue for
the purposes of reliable identification.

Jointing torque and angle of rotation must be observed
without fail (risk of damage).

Necessary preliminary tasks:

Read out fault memory of DME control unit

Switch off ignition

Note:

Installation location of pulse generator for crankshaft is
underneath starter motor. 

Preparatory tasks:

Remove intake air manifold

Detach plug (1) from crankshaft pulse generator (2).

Release screw.

Installation:

Replace aluminium screws.

Tightening torque  12 14 2AZ

.

Withdraw pulse generator (2) from crankcase.

Installation:

Replace sealing ring. 

RA  Replacing crankshaft pulse generator (N54)

BMW AG - TIS

22.02.2013  10:23

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

1 RA Replacing Crankshaft Pulse Generator (N54)|Page 453 > < 3 RA Replacing Spark Plugs (N54, N53)|Page 450