3 Series E90 M3 (S65) SAL
11 78 533
Replacing right oxygen control sensor (S85)
Special tools required:
•
11 7 030
Warning!
Scalding hazard!
Only perform these tasks after exhaust system has cooled
down.
Necessary preliminary tasks:
•
Read out fault memory in Digital Motor Electronics (DME).
•
Remove transmission underbody protection.
Unclip oxygen sensor cable (1).
Release screws (2).
Remove cover (3).
RA Replacing right oxygen control sensor (S85)
BMW AG - TIS
22.02.2013 10:51
Issue status (12/2007) Valid only until next DVD is issued
Copyright