3 Series E93 320i (N46T) CONVER
Turn L-piece (2) under stop screw (3) of coupling fastener.
Adjust coupling fastener as follows:
Set stop screw (3) with adjusting screw (1) such that it comes up
against stop (4).
-
Stop screw (3) of the coupling fastener is aligned flush at
stop (4)
-
The L-piece (2) should ideally rest against the gauge
Bring barrel screws into contact with special tool 54 0 180 in
conjunction with 00 9 450 .
Tightening torque: 0.2 Nm (=20 cNm).
Installation:
Observe screwing sequence of coupling fastener:
Refer to Installing roof module.
1.
Z-direction (coupling fastener to screwing plate, rollover
protection system)
2.
Y-direction (coupling faster to side panel)
3.
X-direction (roof frame to partition wall)
Tightening torque: 54 37 22AZ
.
RA Gauging coupling fastener (without removing and installing roof module)
BMW AG - TIS
24.01.2013 01:45
Issue status (12/2007) Valid only until next DVD is issued
Copyright