5 Series E34 518g (M43) TOUR
If necessary, remove oil pump and control valve,
refer to 11 41 000.
If necessary, remove main flow oil filter,
refer to 11 42 020.
If necessary, remove water pump,
refer to 11 51 000.
Installation
Installation and removal are described separately.
Clean and remove grease from sealing surfaces of crankcase.
Make sure that sleeves are correctly seated.
Replace seal.
Clean groove for rubber profile seal and sealing surfaces on gear
case of remains of seal.
Apply Drei Bond 1209 sealing compound thinly and evenly to
the groove ends, refer to BMW Parts Service.
Seat new rubber seal in groove.
RA Removing and installing, sealing or replacing bottom timing case (M43 / M43TU)
BMW AG - TIS
15.01.2013 12:27
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -