5 Series E34 518g (M43) TOUR
13 80 600
Checking CNG system for leaks and correct
pressure (E34)
After every repair, perform a leak and/or pressure test of all
accessible screw connection points. This is by spraying the
screw connection points with leak tester spray (refer to
BMW Parts Service).
CNG system line routing (screw connection points)
(A) Filler connection
(B) High-pressure non-return valve
(C) Gas tank with retaining frame, gas leak sensor and stop cock
(D) High-pressure relief valve
(1/2/3/4)
Screw connections on filler line between filler connection and high-pressure non-return valve
(5/6)Screw connections on high pressure line between high-pressure non-return valve and gas tank
(7/8/9)
Screw connections on high pressure line between high-pressure non-return valve and high-pressure relief
valve
Inspection I : leak test of screw connections 3/4/5/7/8/9
Inspection II : leak test of screw connections 2/6
RA Checking CNG system for leaks and correct pressure (E34)
BMW AG - TIS
15.01.2013 13:21
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -