5 Series E34 518g (M43) TOUR
13 80 500
Checking and adjusting adjustment of CNG
low pressure regulator
Drain CNG system,
refer to Draining CNG system.
After draining the system, switch off the ignition.
E34
Unfasten screw on low-pressure regulator.
Installation:
Replace O-ring.
Tightening torque 3 Nm.
Check screw for leaks.
E34
Screw measuring adapter 13 8 022 on measuring point (1) into
the low-pressure regulator.
Installation:
Check measuring adapter for leaks
E36
Variant 1: Release screw (1) on low-pressure regulator
(accessible from top of vehicle).
See next illustration for further procedure.
Installation:
Replace O-ring.
Tightening torque 3 Nm.
Check screw for leaks.
RA Checking and adjusting adjustment of CNG low pressure regulator
BMW AG - TIS
15.01.2013 13:25
Issue status (12/2007) Valid only until next DVD is issued
Copyright