5 Series E34 520i (M50) TOUR
Measure gap between secondary tensioner and edge on the
sensor gear.
Note the value.
Connect special tool 12 6 410 to 4/2-way valve for VANOS.
Connect battery.
Ensure that poles are not mixed up.
Camshaft will be adjusted in advanced direction.
Measure gap between secondary tensioner and edge on the
sensor gear.
Note the value.
The difference between both measured values must be at least
8.5 mm.
RA Checking function of VANOS (M50 VANOS)
BMW AG - TIS
19.01.2013 09:34
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -