12 23 000

Checking all glow plugs (M51)

Interrogate fault memory of DDE control unit. Switch off
ignition.

Note:

Before the inspection, charge battery: battery voltage must be
greater than 9 V.

E36:

Unscrew cover on control units.

E39:

Removing cover from control unit box,

refer to 12 63 520

Relay for glow plugs (2): disconnect plug-in connection.

E38:

Removing cover from control unit box,

refer to 12 63 520

Relay for glow plugs (3): disconnect plug-in connection.