bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

10 RA Removing And Installing_sealing Converter Bell Housing (A4S 270R_310R)|Page 690 > < 10 RA Removing And Installing_sealing Converter Bell Housing (A4S 270R_310R)
Page 2
background image

Unfasten retaining screws on radial seal.

Using special tool 00 5 010 in conjunction with a suitable
pressure piece (1), pull radial seal out of converter bell housing.

Installation:

Coat sealing lips of new radial seal with transmission oil.

Install radial seal in converter bell housing and secure with 3
screws.

Tightening torque,

refer to Technical Data 24 11 12AZ.

Remove oil pan (1).

Note:

When cleaning the sealing faces, ensure that no gasket
residue drops into the transmission.

Installation:

Replace seal.

Use new screws.

Tighten all screws firmly home.

In sequence, tighten each screw once down to tightening
torque.

Tightening torque,

refer to Technical Data 24 11 5AZ.

Set transmission upright (converter bell housing facing upwards).

Remove O-ring.

Installation:

Replace O-ring and coat with Vaseline.

RA  Removing and installing/sealing converter bell housing (A4S 270R/310R)

BMW AG - TIS

23.01.2013  07:18

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

10 RA Removing And Installing_sealing Converter Bell Housing (A4S 270R_310R)|Page 690 > < 10 RA Removing And Installing_sealing Converter Bell Housing (A4S 270R_310R)