bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

7 RA Safety Instructions For Handling Refrigerant Oil > < 5 RA Leak-testing With Leak Tester Device|Page 1119
Page 1
background image

64 50 ...

Safety instructions for handling refrigerant
R134a

Warning!

Risk of injury!

Refrigerant circuit is under high pressure! Work on the
refrigerant circuit may only be carried out by experts!

Draw off refrigerant without fail BEFORE all repair work on the
refrigerant circuit.

The refrigerant circuit is depressurized AFTER drawing off!

It is absolutely essential to read and observe the relevant
operating instructions for the A/C service unit used!

Protective measures/rules of conduct:

Wear protective goggles

Wear oil-resistant protective gloves

Do not smoke!

Observe country-specific safety regulations.

First aid measures:

Eye contact:In the event of contact with the eyes, rinse

immediately with plenty of running water and consult an
opthalmologist.

Skin contact: In the event of contact with skin, remove

affected clothing immediately and rinse with plenty of water.

After inhalation: If refrigerant vapours are inhaled in greater

concentrations, remove the person affected to an area of
fresh air and keep them under supervision. Consult a doctor.
If breathing problems are experienced, breathe additional
oxygen. If the person affected is breathing with difficulty or
has stopped breathing, incline the person's head at the neck
and administer the kiss of life.

RA  Safety instructions for handling refrigerant R134a

BMW AG - TIS

23.01.2013  08:18

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

7 RA Safety Instructions For Handling Refrigerant Oil > < 5 RA Leak-testing With Leak Tester Device|Page 1119