64 50 ...

Troubleshooting by pressure measurement
(R 134a)

Note:

The troubleshooting by pressure measurement described in the
following is only possible on A/C systems with uncontrolled
compressors.

This includes among others:

E53

E46M47 up to 09/2001

E38 up to 09/1997

E36, E36/7

E34

E32

E31

Connect service station to car and open both valves on the
charging hoses. Adjust A/C system at control panel as described
for A/C efficiency measurement.

Note:

The following values apply as normal pressure ranges for ambient
temperatures between + 20

°

C and + 40

°

C:

Inlet pressure: 1.0 - 2.2 bar

Outlet pressure: 12 - 22 bar

Normal inlet pressure and high outlet pressure indicate an
overfilled system, a contaminated condenser or a faulty auxiliary
fan.

Remedy:

Draw off, evacuate and refill A/C system. Clean condenser from
outside, check auxiliary fan, replace if necessary.