bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

65 Audio, Navigation And Information System > < 1 RA Instructions For Opening And Replacing Parts In Refrigerant Circuit|Page 1142
Page 1
background image

64 53 ...

Notes on replacing drier bottle or drier insert

The drier bottle or drier insert does not have to be replaced at regular service intervals in a functioning, leakproof A/C
system.

However, the drier bottle or drier insert must be replaced without fail in the event of:

fouling of the refrigerant by filings/shavings (e.g. when the compressor is clamped)

a leaking A/C system or loss of refrigerant

the refrigerant circuit being opened for a period exceeding 24 hours, e.g. during repair work.

RA  Notes on replacing drier bottle or drier insert

BMW AG - TIS

23.01.2013  08:22

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

65 Audio, Navigation And Information System > < 1 RA Instructions For Opening And Replacing Parts In Refrigerant Circuit|Page 1142