5 Series E39 520i (M52TU) SAL
13 54 030
Removing and installing/sealing throttle
assembly (M52TU)
Turn off ignition.
Follow instructions for disconnecting and connecting battery,
refer to General Information MG 12.
Disconnect battery negative lead from battery and lay to one side.
Remove intake filter housing,
refer to 13 71 000.
Remove air-mass flow sensor,
refer to 13 62 560.
Pull throttle cable upwards out of retainer (1) and unhook from
throttle actuator.
Installation:
Adjust throttle cable for throttle actuator,
refer to 35 41.
RA Removing and installing/sealing throttle assembly (M52TU)
BMW AG - TIS
05.02.2013 01:10
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -