5 Series E39 523i (M52TU) SAL
61 20 . . .
Threshold values for battery inspection of all battery (telephone except for telephone
battery)
Safety instructions for handling vehicle battery.
Test step 1 - before charging the battery
Charge state
1)
Starting capability
2)
Test result
Not testable
Charge
less than 50
%
2)
Charge
more than 50
%
less than 75
%
Charge
more than 50
%
more than 75
%
3)
Charge
more than 80
%
more than 75
%
O.K.
Test step 2 - after charging the battery
Charge condition
1)
Starting capability
2)
Test result
Not testable
Defective
less than 50
%
less than 75
%
Charge
more than 50
%
more than 75
%
Charge
1)
Charge condition and starting power must always be evaluated together
2)
When test charging for more than 5 hours, use charger Gossen CG 32 or Siemens / Gossen VB 801
3)
Fully charge until charge state is more than 80
%
.
Note:
If battery was checked on the positive terminal in the engine compartment, repeat check directly on battery for
sake of safety.
RA Threshold values for battery inspection of all battery (telephone except for tel
BMW AG - TIS
14.02.2013 22:53
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -