bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

10 RA Fault 4 > < 8 RA Fault 08 Burner Insert
Page 1
background image

64 99 ...

Fault 1.1 Combustion air blower

Instruction:

Measure voltage on combustion air blower with peripheral box (pin allocation: refer to DIS circuit diagram).

Specified value : 6 V (

±

 1V)

Question

Measure

Is supply voltage O.K.?

No

Replace independent parking heater
control unit,
refer to 64 12 520

Yes

Replace combustion air blower,
refer to 64 12 530

RA  Fault 1.1 Combustion air blower

BMW AG - TIS

22.02.2013  04:49

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

10 RA Fault 4 > < 8 RA Fault 08 Burner Insert