bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

16 Fuel Supply System (M62) > < 1 RA Replacing Air Filter Insert (M60, M62)
Page 1
background image

13 90 500

Replacing tank vent valve (M62)

Interrogate fault memory of DME control unit.

Switch off ignition.

Version 1:

Tank venting valve (1) is fitted in front left wheel arch.

Unfasten plug connection (1).

Release hose clamp (2) and detach fuel hose. 

Open fastener (3) and detach hose.

Installation:

Always replace clip and fuel hose.

Read out fault memory of control unit of Digital Motor
Electronics (DME). Check stored fault messages. Rectify
faults and clear fault memory.

Version 2:

Disconnect plug connection (1).
Release hose clamp (2) and detach hose. 
Remove tank venting valve (3) from bracket (4).

Open fastener and detach fuel hose (5).

Installation:

Always replace clip and fuel hose.

Read out fault memory of control unit of Digital Motor
Electronics (DME). Check stored fault messages. Rectify
faults and clear fault memory.

RA  Replacing tank vent valve (M62)

BMW AG - TIS

20.02.2013  13:19

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

16 Fuel Supply System (M62) > < 1 RA Replacing Air Filter Insert (M60, M62)