13 71 000

Removing and installing suction-filter
housing (M60, M62)

Disconnect plug connection (1) from mass air flow sensor.

Unfasten hose clip (2).

Pull off hose.

E38 M62: Disconnect plug connection on temperature sensor for
intake air.

Open clips (1).

Remove air-mass sensor.

Installation:

Replace gasket (1) between mass air flow sensor and upper
section of air filter.

To facilitate assembly, coat gasket with acid-free grease.

M60 B30:

Loosen hose clamp.

Pull off hose.