5 Series E60 525i (N52K) SAL
61 12 013
Replacing battery negative lead
Warning!
Observe safety instructions for handling vehicle battery.
Read and comply with notes and instructions on intelligent
battery sensor.
Necessary preliminary tasks:
•
Remove luggage compartment trim on side panel on right
Security version:
•
Remove luggage compartment equipment carrier
Slacken nut (1) on negative battery terminal.
Tightening torque 61 21 1AZ
.
Important!
Do not under any circumstances use force to pull off pole
shoe.
Do not under any circumstances release socket-head cap
screw of IBS.
Detach negative battery lead with intelligent battery sensor (IBS)
in upward direction.
Disconnect plug connection (2).
Disconnect plug connection (3).
Release nut (4) and battery negative lead (5).
Tightening torque 61 21 2AZ
.
RA Replacing battery negative lead
BMW AG - TIS
18.02.2013 03:49
Issue status (12/2007) Valid only until next DVD is issued