5 Series E60 530Li (N52) SAL
Recycling:
Carry out the cleaning operation in a suitable washing bay as the
emerging cleaning agent escapes through the drain openings in
the transmission tunnel.
After completing cleaning, allow car to drip-dry for approx. 5
minutes.
Necessary preliminary tasks:
•
Remove fresh air duct
Partially detach transmission underbody protection (6) for
draining cleaning fluid:
Release screws (2 ... 4) in rear area and press heat shield (5)
away.
Connect special tool 64 1 480 (spray lance) to spraying
equipment.
Insert spray lance (1) through opening (2) to fresh air duct.
By moving spray lance (1) back and forth, spray a uniform
amount of cleaning agent onto evaporator.
RA Cleaning evaporator
BMW AG - TIS
22.02.2013 07:52
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -