5 Series E60 545i (N62) SAL
Release screw (1).
Disconnect hydraulic lines (2) to transmission fluid cooler.
Installation:
Replace sealing rings.
Crank engine at vibration damper in direction of rotation until
screw is visible in opening.
Release all screws of torque converter with special tool
24 1 110 .
Crank engine further and release remaining 3 bolts.
Tightening torque 24 40 1AZ
.
Prepare special tool (1) 24 4 161 with shaped piece (2)
24 4 165 .
Illustration similar.
Insert special tool 24 4 160 into opening of transmission housing
and clamp gently with screw (1).
Twist in screw (2) and clamp down.
Then tighten down screw (1).
RA Removing and installing automatic transmission (6HP26Z/ N62, N62TU)
BMW AG - TIS
22.02.2013 14:47
Issue status (12/2007) Valid only until next DVD is issued
Copyright