5 Series E61 530i (N52K) TOUR
34 00 050
Bleeding brake system with DSC
Necessary preliminary tasks:
•
Remove lower section of microfilter housing.
•
Read and comply with General Information.
Observe the filling and bleeding instructions when replacing or
repairing:
-
Replace
-
Hydraulic unit
-
Components and connecting lines which are fitted between
these assemblies.
Connect bleeder unit with max. 2 bar filling pressure.
A second person is needed to help carry out this work.
Important!
Check relevant Operating Instructions for each device.
Charging pressure should not exceed 2 bar.
-
Connect BMW Diagnosis and Information System (DIS).
-
Select path: Service functions - Chassis/Suspension - Slip
control systems - Bleeding procedure.
-
Connect bleeder unit to expansion tank and switch on.
Flushing brake system completely
Connect bleeder hose with collecting tray to bleeder valve on rear
right brake caliper.
Open bleeder valve and purge until clear, bubble-free brake fluid
emerges.
Close bleed valve.
Follow same procedure on rear left, front right and front left wheel
brake.