6 Series 645Ci (N62) Coupe
12 14 526
Replacing pulse generator on right inlet
camshaft (N62, N62TU)
(cylinder bank 1 to 4)
Necessary preliminary tasks:
•
Read out fault memory of DME control unit; if necessary,
work through test schedules
•
Switch off ignition
•
Remove acoustic cover
•
Remove right ignition coil cover
Release plug connector (1) and pull off.
Release screw.
Remove pulse generator (2).
Installation:
Replace sealing ring and coat with antiseize agent.
RA Replacing pulse generator on right inlet camshaft (N62, N62TU)
BMW AG - TIS
18.01.2013 06:13
Issue status (12/2007) Valid only until next DVD is issued