67 62 000
Removing and installing/replacing flat motor
for front left or right power window unit
Necessary preliminary tasks:
•
Release sound insulation on front door
Unfasten plug connection (1) and disconnect.
Release screws (2).
Detach flat motor for power window unit (3) in direction of arrow
from power window unit (4) and remove.
Replacement:
A normalization must be carried out in order to activate anti-
trapping protection.
Operating sequence for normalization:
•
Open corresponding window completely.
•
Operate corresponding power window switch in "Close"
position (second switch stage).
•
Once the upper end position has been reached, hold power
window switch down for approx. 1 second more.
Normalization is thus completed.
Note:
Carry out function check (one-touch function, anti-trapping
protection and, if necessary, comfort function).
RA Removing and installing/replacing flat motor for front left or right power windo