6 Series M6 (S85) Coupe
23 14 504
Replacing wiring harness (GS7S47BG SMG)
Disconnect connector (1).
Detach cable (2) from bracket.
Disconnect plugs (1) and (2) from valve block.
Release cable tie (3).
Installation:
Use maximum-temperature-resistant cable ties (approx. 140
°
).
Important!
Sensor strip (4) must not be separated from actuator
block (5).
Sensor strip and actuator block may only be replaced as a
single unit.
Important!
When installing, pay attention without fail to yellow
markings (2).
Installation:
Cut open sticker (1) over course of cable.
Tape over again with transparent adhesive tape.
Disconnect connector (1).
Release wiring harness (2) from holders.
RA Replacing wiring harness (GS7S47BG SMG)
BMW AG - TIS
19.01.2013 14:17
Issue status (12/2007) Valid only until next DVD is issued
Copyright