Replacement:

Important!

Before modifying holder on electric motor:

Check installation location.

Mark holder (1) in relation to screws (2)

Release screws (2) and convert holder (1).

New electric motors are supplied with blind holes and new
screws.

The blind holes have no threads - these are cut by the screws.

After completing work:

Top up fluid level in hydraulic system

Clear fault memory

RA  Replacing electric motor on hydraulic pump (GS7S47BG SMG)