Disconnect plug connection for IBS (3).
If necessary, open cable shoe cover (4).
Release nut on luggage compartment distribution box. Tightening
torque 61 21 2AZ
.
Open cable shoe mounting (1).
Release screw (2). Tightening torque
61 12 3AZ
.
Release cable shoe mounting (1) from positive battery lead (3)
and remove.
Installation:
Risk of short circuits!
Make sure cable shoe mounting (1) is correctly seated on battery
positive lead (3).
Release battery positive lead (1) from fastening points (2).
If necessary, release cable ties.
Installation:
Make sure battery positive cable (1) is correctly routed.
RA Replacing battery positive lead (from battery to luggage compartment connector)