6 Series E64 M6 (S85) CONVER

13 62 604
Replacing pulse generator on left exhaust
camshaft (S85)
(cylinder bank 6 to 10)
Necessary preliminary tasks:
•
Read out fault memory of DME control unit; if necessary,
work through test schedules
•
Switch off ignition
•
Remove left intake filter housing
•
Remove left ignition coil cover
Release plug connector (1) and pull off.
Release screw.
Remove pulse generator (2).
Installation:
Replace sealing ring and coat with antiseize agent.
Note:
Now clear the fault memory.
RA Replacing pulse generator on left exhaust camshaft (S85)
BMW AG - TIS
07.02.2013 02:44
Issue status (12/2007) Valid only until next DVD is issued
Copyright