bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Replacing Electric Motor On Hydraulic Pump (GS7S47BG SMG)|Page 739 > < 3 RA Replacing Electric Motor On Hydraulic Pump (GS7S47BG SMG)
Page 2
background image

Release cable tie (1).

Release screw (2).

Tightening torque  23 41 26AZ

.

Installation:

Use high-temperature-resistant cable ties (approx. 140 

°

).

Unclip oxygen sensor plugs (1).

Release nut (2) and remove holder (3).

Unclip return line (1) from holder and place to one side.

Unlock and disconnect plug (2).

Important!

Risk of damage!

Adhere to conditions of absolute cleanliness when carrying
out the following tasks.

RA  Replacing electric motor on hydraulic pump (GS7S47BG SMG)

BMW AG - TIS

07.02.2013  03:53

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

3 RA Replacing Electric Motor On Hydraulic Pump (GS7S47BG SMG)|Page 739 > < 3 RA Replacing Electric Motor On Hydraulic Pump (GS7S47BG SMG)