bmw Workshop Repair Guides

BMW 7 Series E38 740iL SAL Workshop Service and Repair Manuals

1 RA Removing And Installing Or Replacing Battery Positive Lead (between Starter, Alt|Page 729 > < 1 RA Removing And Installing Or Replacing Battery Positive Lead (between Starter, Alt|Page 727
Page 5
background image

Unfasten cable connector (1).

Remove battery positive lead (3) from lead holders (2).

Unfasten cable clip (2).

Remove battery positive lead from lead holders (1).

Press press-stud fasteners (1...4) in succession and at same time
raise acoustic cover slightly.

Remove acoustic cover once all four press-stud fasteners have
been unlocked.

Installation:

Position acoustic cover and press downwards until press-stud
fasteners (1...4) click into place.

Remove seal caps (2) and release screws.

Remove cover.

Detach battery positive lead from battery positive support point (1).

RA  Removing and installing or replacing battery positive lead (between starter, alt

BMW AG - TIS

14.02.2013  03:43

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 5 -