Installation:
Ensure guides (1) and (2) are correctly seated.
If necessary, replace rubber mount.
Water valve (Duo) without auxiliary water pump:
Unlock plug connection (1) and disconnect.
Release hose clamps (2) and detach water hoses.
Pull water valve for heater (3) in direction of arrow out of rubber
mounts.
Installation:
Ensure guides (1) and (2) are correctly seated.
If necessary, replace rubber mount.
All:
RA Replacing water valve for heater