Caution!

Non-return valve (A) must be closed for high pressure
measurements - damage to pressure gauge.

A = non-return valve - low pressure 0...15 bar - closed

B = non-return valve - high pressure 0...150 bar - open

Unfasten control rod joint from lever on control valve.

Start engine.

Move lever on control valve in forwards direction of travel = tail of
vehicle lifts.

Read off pressure. Nominal value, max. bar,

refer to Technical Data.

Lever on control valve

a) move into centre position

b) move in reverse direction of travel and read off pressure in
each case. Nominal value, min. bar,

refer to Technical Data.